Assuring Reliable Start and Clean Run for Critical Power Generators Fuel Systems for Critical Generators

Duplex Pumps, Day Tanks, Filter Polishers, Fill Stations, and Controls. Integrated Reliable Fuel Systems for Data Centers, Hospitals, Infrastructure, and Buildings.

Read More DEF Systems for Generator SCR

DEF Tanks, Pumps, Filters, Fill Stations, Sensors and Controls.  Integrated Systems for Generator SCR Reliability because if DEF Fails then Power Fails.

Read More GenApp Controls and Remote Monitoring 

Precision fluid flow and environmental control. Site monitoring of systems  for compliance and readiness.  Cloud interface devices with secure database and see - anywhere user interface

Read More Lube Products for CHP and Primary Gensets

Auto-Lube and Waste Oil Systems for Combined Heat and Power (CHP) Gensets for Prime Power, and other continuous run applications.  

Read More Product Finder

Find products to fit your specific needs.

Technical Documents

Browse all technical documentation.

Customer Support

Talk to our customer support team.

 How to Design a Generator DEF System

Diesel Exhaust Fluid (DEF) is a critical component now of generator systems, because it is required to meet emissions regulations. DEF problems can require that generators shut-down rather than operate outside emissions limits.

Generator DEF Systems are much different from truck engines primarily because of the volume of static inventory needed. So storage and temperature of storage is important

This guide starts with a simple storage system. Each subsequent step results in a functional system, so you can just stop after the step that fulfills your requirements.

Download the Design Guide  How to Design a Life Safety Generator Fuel System

Life Safety Generator Fuel Systems can be complex. They need to operate reliably and meet applicable building codes. The configurations are often dictated by the very limited space available in the building design.

To make them easier to understand we break down the design process adding elements as needed to accomplish your design goals. Each Step results in a functional system, so you can just stop after the step that fulfills your requirements.

Download the Design Guide Latest from Earthsafe DEF for Generators Top 10 Questions What is DEF? Diesel Exhaust Fluid (DEF) is a mixture of Urea in Deionized water in a 32.5 % concentration. It is used as a consumable fluid in diesel engine emissions control using Selective Catalytic Reduction (SCR). How Much DEF do I Need? A good rule of thumb for generators is that DEF consumption will be about 10% of diesel consumption. Read More End-of-Life PLC Upgrades for Allen Bradley and Siemens

End of Life for Micrologix 1000/1500:

There are several million Micrologix 1000 PLCs in service around the world, including thousands in critical service in data center equipment. Hundreds of Dot‐Com Era (1998 – 2002) data centers are still in service throughout the US and world.

Many of these facilities are very valuable because they occupy locations close to large cities and fiber optic infrastructure.  Earthsafe built fuel systems for many of these facilities, and our systems have operated reliably over that time with very little maintenance.


Read More Clean Diesel Rules for Generators: NFPA 110 Drilldown

Clean Fuel for Generators: Drilldown of NFPA 110 Rules

For those of you who just don’t like to read, or have only a moderate tolerance for reading codes and regulations, we have the done the dirty work for you. 

NFPA 110 “Standard for Emergency and Standby Power Systems” is the standard for people who own and operate buildings with emergency generators.  It’s the starting point of what a building owner should consider as good practice, and may go further toward a legal requirement since it is referenced in building codes.

Read More